N1C LX N1C.LX2200 2.2kVA Rack/Tower UPS - 2U Rack/Tower - 27 Minute Stand-by - 120 V AC Input - 110 V AC, 120 V AC Output - Single Phase - Sine Wave - USB - LED Display - 8 x NEMA 5-15/20R
2U Rack/Tower - 27 Minute Stand-by - 120 V AC Input - 110 V AC, 120 V AC Output - Single Phase - Sine Wave - USB - LED Display - 8 x NEMA 5-15/20R
DC System Voltage | 48 V DC |
Input Power Factor | 0.9 |
Load Capacity (VA) | 2200 VA |
Load Capacity (W) | 1980 W |
Output Frequency | 60 Hz |
Phase | Single Phase |
Receptacle Detail | 8 x NEMA 5-15/20R |
Waveform Type | Sine Wave |
Alarm | Abnormal Input Voltage |
Alarm | UPS Failure |
Alarm | Low Battery |
Application/Usage | Computer Room |
Application/Usage | Network Hub |
Application/Usage | Commercial |
Application/Usage | Data Center |
Application/Usage | Precision Instrument |
Application/Usage | Rack Device |
Application/Usage | Router |
Application/Usage | POS Terminal |
Application/Usage | Network Device |
Backup/Run Time (Full Load) | 27 Minute |
Backup/Run Time (Half Load) | 56 Minute |
Battery capacity | 24000 mAh |
Battery Chemistry | Lithium Ion (Li-Ion) |
Brand Name | N1C |
Depth | 20.1" |
Display | LED |
Form factor | Rack/Tower |
Height | 3.4" |
Hot Swappable | Yes |
Input voltage | 120 V AC |
Limited Warranty | 10 Year |
Load Capacity | 2200 VA/1980 W |
Manufacturer | N1C Technologies Inc. |
Manufacturer Part Number | N1C.LX2200 |
Manufacturer Website Address | http://www.n1critical.com |
Marketing Information | Life Span: The average life span of a VRLA battery is 4-6 years in ideal conditions. N1C Li-Ion battery life span is 10-15 year in nearly all conditions. Long life batteries reduce the burden and cost of down time and maintenance. High Power Density: Lithium Ion batteries have over 5 times the Energy density and take up about 1/3 the space of a VRLA based solution that delivers the same power. This means more power in the same or smaller footprint. Charge and Recharge: Efficiency: N1C Lithium Ion batteries can be charged/ discharged over 1000 times versus 200-400 charges/ discharges for standard VRLA batteries. N1C Lithium UPS units include built in chargers capable of 1-hour recharge times compared to 4-10 hour recharge times of VRLA battery UPS systems. Smaller Footprint: A smaller footprint translates to reduced cooling requirements as well as about a two thirds reduction in weight. This offers the installation flexibility needed by many IT departments. Environmentally Friendly: Other than the obvious that Lithium Ion batteries do not use Lead there are many other "green" benefits to Lithium. Lithium batteries require less charging time and power need to be replaced less often and take less energy to produce and transport. Heat Tolerant: L-Series UPS units can withstand working temperatures up to 140 ?F. Where VRLA battery life is reduced by half for every 10 ?F over 70F Li-Ion battery life is unaffected. |
Network Management | SNMP |
Output voltage | 110 V AC |
Package Contents | - LX N1C.LX2200 2.2kVA Rack/Tower UPS
- Rack Rails
|
Plug/Connector Type | NEMA 5-20P |
Product Name | LX N1C.LX2200 2.2kVA Rack/Tower UPS |
Product Series | LX |
Product Type | Double Conversion Online UPS |
Rack Height | 2U |
Receptacle Type | NEMA 5-15/20R |
Status Indicators | LED Display: - Battery Status
- Battery Level
- Battery Fault
- Alarms
|
Weight (Approximate) | 33.50 lb |
Width | 17.2" |