Tripp Lite Smart Online UPS 3000VA 2700W 208/120V Step-Down Transformer 4U
$3,425.18 Retail $5,565.46 |
- Offers protected 208V and 120V network-grade output power for critical IT applications
- Zero transfer time between on-line and battery modes for uninterrupted operation
- UPS + step-down transformer offer power protection of both 208V and 120V network devices
- Optional external battery packs provide additional runtime for extended-run applications
- Optional WEBCARDLX network interface required to use Auto Probe feature
- 2-year limited warranty
- $250,000 Ultimate Lifetime Insurance
4U Rack/Tower - 3 Hour Recharge - 5 Minute Stand-by - 230 V AC Input - 120 V AC, 208 V AC Output - 12 x NEMA 5-15/20R, 6 x NEMA 6-15/20R, 2 x NEMA L6-20R
Product Specifications
DC System Voltage | 72 V DC |
DC System Voltage | 72 V DC |
Energy Saving | High Efficiency Economy Mode Operation; Individually Controllable Load Banks |
Energy Saving | High Efficiency Economy Mode Operation; Individually Controllable Load Banks |
Load Capacity (VA) | 3000 VA |
Load Capacity (VA) | 3000 VA |
Load Capacity (W) | 2700 W |
Load Capacity (W) | 2700 W |
Maximum Operating Elevation | 9842.52 ft |
Maximum Operating Elevation | 9842.52 ft |
Output Frequency | 60 Hz |
Output Frequency | 60 Hz |
Phase | Single Phase |
Phase | Single Phase |
Receptacle Detail | 12 x NEMA 5-15/20R |
Receptacle Detail | 2 x NEMA L6-20R |
Receptacle Detail | 12 x NEMA 5-15/20R |
Receptacle Detail | 6 x NEMA 6-15/20R |
Receptacle Detail | 2 x NEMA L6-20R |
Receptacle Detail | 6 x NEMA 6-15/20R |
Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
Waveform Type | Pure Sine Wave |
Waveform Type | Pure Sine Wave |
Alarm | Low Battery |
Alarm | Fault |
Alarm | Power Failure |
Alarm | Overload |
Alarm | Fault |
Alarm | Low Battery |
Alarm | Power Failure |
Alarm | Overload |
Application/Usage | Data Center |
Application/Usage | Data Center |
Application/Usage | Network Equipment |
Application/Usage | Mission Critical Equipment |
Application/Usage | Computer Room |
Application/Usage | Network Closet |
Application/Usage | Server |
Application/Usage | Network Equipment |
Application/Usage | Server |
Application/Usage | Network Closet |
Application/Usage | Computer Room |
Application/Usage | Mission Critical Equipment |
Backup/Run Time (Full Load) | 5 Minute |
Backup/Run Time (Full Load) | 5 Minute |
Backup/Run Time (Half Load) | 13.50 Minute |
Backup/Run Time (Half Load) | 13.50 Minute |
Brand Name | Tripp Lite |
Brand Name | Tripp Lite |
Country of origin | China |
Country of origin | China |
Depth | 24.3" |
Depth | 24.3" |
Environmental Certification | RoHS |
Environmental Certification | WEEE |
Environmental Certification | RoHS |
Environmental Certification | WEEE |
Form factor | Rack/Tower |
Form factor | Rack/Tower |
Height | 7" |
Height | 7" |
Hot Swappable | Yes |
Hot Swappable | Yes |
Input voltage | 230 V AC |
Input voltage | 230 V AC |
Limited Warranty | 2 Year |
Limited Warranty | 2 Year |
Load Capacity | 3000 VA/2700 W |
Load Capacity | 3000 VA/2700 W |
Manufacturer | Tripp Lite by Eaton |
Manufacturer | Tripp Lite by Eaton |
Manufacturer Part Number | SU3000LCD2UHVTF |
Manufacturer Part Number | SU3000LCD2UHVTF |
Manufacturer Website Address | http://www.tripplite.com |
Manufacturer Website Address | http://www.tripplite.com |
Marketing Information | 2U Double-Conversion UPS Protects Equipment against Damage Downtime and Data Loss This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity high 0.9 power factor 570 joules of surge suppression true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet computer room and data center equipment. With the included 2U step-down transformer this 3kVA UPS system can support both low- and high-voltage equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy from precise power for sensitive systems to the highest possible electrical efficiency while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency Max Quality Frequency Regulation and Auto Adaptive which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor. Individually Controllable Load Banks Let You Access and Control Outlets Remotely The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks allowing you to reboot select components or shed loads remotely. Reliable Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W) keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime the UPS supports "smart" external battery packs such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life. Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational even during UPS fault conditions. Automatically Turns Back On When Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode detailed UPS status and site-power information as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output battery and fault status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included. |
Marketing Information | 2U Double-Conversion UPS Protects Equipment against Damage Downtime and Data Loss This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity high 0.9 power factor 570 joules of surge suppression true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet computer room and data center equipment. With the included 2U step-down transformer this 3kVA UPS system can support both low- and high-voltage equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy from precise power for sensitive systems to the highest possible electrical efficiency while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency Max Quality Frequency Regulation and Auto Adaptive which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor. Individually Controllable Load Banks Let You Access and Control Outlets Remotely The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks allowing you to reboot select components or shed loads remotely. Reliable Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W) keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime the UPS supports "smart" external battery packs such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life. Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational even during UPS fault conditions. Automatically Turns Back On When Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode detailed UPS status and site-power information as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output battery and fault status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included. |
Maximum Operating Temperature | 104°F (40°C) |
Maximum Operating Temperature | 104°F (40°C) |
Network Management | SNMP/DB9/USB |
Network Management | SNMP/DB9/USB |
Output voltage | 208 V AC |
Output voltage | 120 V AC |
Output voltage | 208 V AC |
Output voltage | 120 V AC |
Package Contents |
|
Package Contents |
|
Plug/Connector Type | NEMA L6-20P |
Plug/Connector Type | NEMA L6-20P |
Product Line | SmartOnline |
Product Line | SmartOnline |
Product Name | SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS |
Product Name | SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS |
Product Type | Dual Conversion Online UPS |
Product Type | Dual Conversion Online UPS |
Product Type | Double Conversion Online UPS |
Rack Height | 4U |
Rack Height | 4U |
Material Safety Data Sheet
A Material Safety Data Sheet (MSDS) is a document that contains information on the potential hazards (health, fire, reactivity and environmental) and how to work safely with the chemical product.