Load Capacity (VA) | 1000 VA |
Load Capacity (W) | 770 W |
Maximum Operating Elevation | 9842.52 ft |
Output Frequency | 60 Hz |
Waveform Type | Sine Wave |
Application/Usage | Server |
Application/Usage | Virtual Machine |
Backup/Run Time (Full Load) | 5 Minute |
Backup/Run Time (Half Load) | 12 Minute |
Battery capacity | 9000 mAh |
Battery Characteristics | Maintenance-free Leak-proof |
Battery Chemistry | Sealed Lead Acid (VRLA) |
Brand Name | Lenovo |
Depth | 13.6" |
Energy Star | No |
Height | 9.2" |
Hot Swappable | Yes |
Input Voltage Range | 100 V AC - 125 V AC |
Load Capacity | 1000 VA/770 W |
Manufacturer | Lenovo Group Limited |
Manufacturer Part Number | 55951AX |
Manufacturer Website Address | http://www.lenovo.com/us/en/ |
Marketing Information | The T1kVA and T1.5kVA Tower Uninterruptible Power Supply (UPS) offerings provide power protection with increased efficiency and simplified power management to safeguard the high-availability of Lenovo server environments. With efficiency ratings of up to 97% these compact tower designs can help reduce energy usage without compromising performance or reliability. Did you know? T1kVA and T1.5kVA Tower UPS units feature Advanced Battery Management (ABM) technology that uses a unique three-stage charging technique that significantly extends battery service life and optimizes recharge time compared to traditional charging. T1kVA and T1.5kVA Tower UPS units can enhance system availability with individual receptacle groups or load segments that can be programmed and controlled which allows mission-critical devices to be prioritized during shutdown to preserve battery run time if there is a prolonged power outage. T1kVA and T1.5kVA Tower UPS units come standard with UPS Power Manager (UPM) power management software that integrates seamlessly with the major virtual platforms which enables you to view and manage your entire power system from your current dashboard. It also triggers live migration during power outages and avoids data loss by gracefully shutting down virtual machines and hosts in a cluster if there is an extended power outage. |
Maximum Operating Temperature | 95°F (35°C) |
Output voltage | 125 V AC |
Output voltage | 100 V AC |
Output voltage | 120 V AC |
Product Model | T1kVA |
Product Name | T1kVA Tower UPS |
Product Type | Line-interactive UPS |
Status Indicators | LED Indicators:
|
UPC Alternates | 883436548212 |
Weight (Approximate) | 25.35 lb |
Width | 5.9" |