DC System Voltage | 120 V DC |
DC System Voltage | 120 V DC |
Energy Saving | High efficiency economy mode operation; Schedulable daily hours of economy mode operation |
Energy Saving | High efficiency economy mode operation; Schedulable daily hours of economy mode operation |
Environmental Sensors | Humidity Sensor |
Environmental Sensors | Humidity Sensor |
Environmental Sensors | Temperature Sensor |
Environmental Sensors | Temperature Sensor |
Maximum Operating Elevation | 3280 ft |
Maximum Operating Elevation | 3280 ft |
Output Frequency | 60 Hz |
Output Frequency | 60 Hz |
Overload Protection | Yes |
Overload Protection | Yes |
Phase | Three Phase |
Phase | Three Phase |
Storage Temperature | 32°F (0°C) - 95°F (35°C) |
Storage Temperature | 32°F (0°C) - 95°F (35°C) |
Waveform Type | Pure Sine Wave |
Waveform Type | Pure Sine Wave |
Alarm | Bypass Mode |
Alarm | Low Battery |
Alarm | Overload |
Alarm | Bypass Mode |
Alarm | Overload |
Alarm | Shutdown |
Alarm | Shutdown |
Alarm | Low Battery |
Application/Usage | Critical System |
Application/Usage | Finance |
Application/Usage | Data Center |
Application/Usage | Finance |
Application/Usage | Data Center |
Application/Usage | Telecommunication |
Application/Usage | Banking |
Application/Usage | Government |
Application/Usage | Education |
Application/Usage | Healthcare |
Application/Usage | Server Room |
Application/Usage | Network |
Application/Usage | Healthcare |
Application/Usage | Telecommunication |
Application/Usage | Banking |
Application/Usage | Industrial |
Application/Usage | Government |
Application/Usage | Education |
Application/Usage | IT Equipment |
Application/Usage | Critical System |
Application/Usage | IT Equipment |
Application/Usage | Industrial |
Application/Usage | Network |
Application/Usage | Server Room |
Application/Usage | Manufacturing Facility |
Application/Usage | Edge Computing |
Application/Usage | Manufacturing Facility |
Application/Usage | Edge Computing |
Brand Name | Tripp Lite |
Brand Name | Tripp Lite |
Country of origin | China |
Country of origin | China |
Depth | 33.5" |
Depth | 33.5" |
Environmental Certification | RoHS |
Environmental Certification | RoHS |
Form factor | Tower |
Form factor | Tower |
Height | 63" |
Height | 63" |
Input voltage | 220 V AC |
Input voltage | 127 V AC |
Input voltage | 120 V AC |
Input voltage | 127 V AC |
Input voltage | 120 V AC |
Input voltage | 230 V AC |
Input voltage | 220 V AC |
Input voltage | 230 V AC |
Limited Warranty | 2 Year |
Limited Warranty | 2 Year |
Load Capacity | 100 kVA |
Load Capacity | 100 kVA |
Manufacturer | Tripp Lite by Eaton |
Manufacturer | Tripp Lite by Eaton |
Manufacturer Part Number | S3M100K |
Manufacturer Part Number | S3M100K |
Manufacturer Website Address | http://www.tripplite.com |
Manufacturer Website Address | http://www.tripplite.com |
Marketing Information | Battery Backup and VFI Operation Protect Critical Loads
The SmartOnline® S3M100K IGBT UPS supports the continuous availability of your most important operational and IT equipment loads through all power conditions providing a compact backup power platform that's easy to manage and inexpensive to operate. Sophisticated voltage- and frequency-independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 100kVA/kW of clean continuous power this 3-phase UPS system is ideally suited for critical applications in banking education healthcare government and manufacturing sectors. Best-in-Class Footprint for Easy Integration into Your Network Application
The UPS market's smallest footprint for 3-phase 208V systems lets you install the S3M100K in spaces that would otherwise have required expensive retrofitting. By achieving its compact size without compromising runtime reliability or functionality the S3M100K is recommended for data centers colocation facilities and edge computing environments that require high efficiency high performance and clean reliable power protection while preserving as much space as possible for revenue-generating server racks. Efficient Operation and Design Reduces Cost of Ownership
ENERGY STAR 2.0-certified technology provides high operational efficiency to save on utility and cooling costs as well as protect the environment. This UPS achieves up to 94% efficiency in double-conversion mode and up to 98% in ECO mode reducing your power and cooling costs. Unity output power factor (1.0) lets you support more equipment. A low THDi (<3%) improves generator compatibility. A low THDv (?2%) and active power factor correction with DSP control improve output performance. The hardware and firmware platform design reduces the number of unique boards improving mean time to repair (MTTR) and resulting in reduced downtime. Automatic and maintenance bypass transfer UPS load to utility power during faults overloads and maintenance which also avoids costly system downtime. External Batteries Supply Reliable Backup with Expandable Runtime Options
The S3M100K uses external battery cabinets including BP240V65L and BP240V100L (sold separately) to provide backup support in case of a power failure. These cabinets are available with or without internal batteries. No internal batteries are included with the S3M100K. A one-touch cold-start button powers up the UPS with battery power only. Intuitive LCD Interface Delivers Important Performance Information at a Glance
The large five-inch touchscreen LCD panel displays critical operating conditions and diagnostic data including battery and load status. Four LEDs provide information about AC bypass battery and fault status. Remote Network Monitoring and Control Available 24 Hours a Day
The optional Java-free WEBCARDLXMINI network management card (sold separately) enables remote management through embedded HTML5 web SSH/telnet and SNMP interfaces as well as integration with a wide range of network management systems and DCIM platforms. WEBCARDLXMINI also supports EnviroSense2 (sold separately) which monitors temperature humidity and other environmental factors. Three MODBUS ports (RS-485 USB RS-232) may also be used to monitor and manage the UPS. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies. |
Marketing Information | Battery Backup and VFI Operation Protect Critical Loads
The SmartOnline® S3M100K IGBT UPS supports the continuous availability of your most important operational and IT equipment loads through all power conditions providing a compact backup power platform that's easy to manage and inexpensive to operate. Sophisticated voltage- and frequency-independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 100kVA/kW of clean continuous power this 3-phase UPS system is ideally suited for critical applications in banking education healthcare government and manufacturing sectors. Best-in-Class Footprint for Easy Integration into Your Network Application
The UPS market's smallest footprint for 3-phase 208V systems lets you install the S3M100K in spaces that would otherwise have required expensive retrofitting. By achieving its compact size without compromising runtime reliability or functionality the S3M100K is recommended for data centers colocation facilities and edge computing environments that require high efficiency high performance and clean reliable power protection while preserving as much space as possible for revenue-generating server racks. Efficient Operation and Design Reduces Cost of Ownership
ENERGY STAR 2.0-certified technology provides high operational efficiency to save on utility and cooling costs as well as protect the environment. This UPS achieves up to 94% efficiency in double-conversion mode and up to 98% in ECO mode reducing your power and cooling costs. Unity output power factor (1.0) lets you support more equipment. A low THDi (<3%) improves generator compatibility. A low THDv (?2%) and active power factor correction with DSP control improve output performance. The hardware and firmware platform design reduces the number of unique boards improving mean time to repair (MTTR) and resulting in reduced downtime. Automatic and maintenance bypass transfer UPS load to utility power during faults overloads and maintenance which also avoids costly system downtime. External Batteries Supply Reliable Backup with Expandable Runtime Options
The S3M100K uses external battery cabinets including BP240V65L and BP240V100L (sold separately) to provide backup support in case of a power failure. These cabinets are available with or without internal batteries. No internal batteries are included with the S3M100K. A one-touch cold-start button powers up the UPS with battery power only. Intuitive LCD Interface Delivers Important Performance Information at a Glance
The large five-inch touchscreen LCD panel displays critical operating conditions and diagnostic data including battery and load status. Four LEDs provide information about AC bypass battery and fault status. Remote Network Monitoring and Control Available 24 Hours a Day
The optional Java-free WEBCARDLXMINI network management card (sold separately) enables remote management through embedded HTML5 web SSH/telnet and SNMP interfaces as well as integration with a wide range of network management systems and DCIM platforms. WEBCARDLXMINI also supports EnviroSense2 (sold separately) which monitors temperature humidity and other environmental factors. Three MODBUS ports (RS-485 USB RS-232) may also be used to monitor and manage the UPS. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies. |
Maximum Operating Temperature | 104°F (40°C) |
Maximum Operating Temperature | 104°F (40°C) |
Network Management | Telnet |
Network Management | Telnet |
Network Management | SSH |
Network Management | SNMP Manageable |
Network Management | SSH |
Network Management | SNMP Manageable |
Output voltage | 208 V AC |
Output voltage | 208 V AC |
Package Contents | - SmartOnline S3M100K 100kVA Tower UPS
- RS-232 Cable (Male/Female) 5 ft. (1.5 m)
- Parallel Cable (Male/Female) 5 ft. (1.5 m)
- USB Cable 5 ft. (1.5 m)
- Dry Contact Connector (Green)
- Owner's Manual
|