Tripp Lite PDU 3-Phase Monitored 6 C13 12 C19 208V 50A 14.4kW 0URM TAA
$1,440.51 Retail $2,366.20 |
- Advanced remote capabilities include outlet-level current monitoring in real time
- 6 C13 and 12 C19 208V outlets distribute AC power to connected equipment
- Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
- Color touchscreen LCD provides current levels, environmental data and network info
- Installs in 0U of rack space in standard 19 in. racks using included mounting hardware
- 2-year limited warranty
Monitored - Hubbel CS8365C 50A - 6 x IEC 60320 C13, 12 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical/Toolless - Rack-mountable - TAA Compliant
Product Specifications
Mounting Orientation | Vertical/Toolless |
Mounting Orientation | Vertical/Toolless |
Mounting Orientation | Vertical/Toolless |
PDU Type | Monitored |
PDU Type | Monitored |
PDU Type | Monitored |
Phase | Three Phase |
Phase | Three Phase |
Phase | Three Phase |
Plug/Connector Detail | 1 x Hubbel CS8365C 50A |
Plug/Connector Detail | 1 x Hubbel CS8365C 50A |
Plug/Connector Detail | 1 x Hubbel CS8365C 50A |
Power Rating (Watt) | 14.40 kW |
Power Rating (Watt) | 14.40 kW |
Power Rating (Watt) | 14.40 kW |
Receptacle Detail | 6 x IEC 60320 C13 |
Receptacle Detail | 12 x IEC 60320 C19 |
Receptacle Detail | 6 x IEC 60320 C13 |
Receptacle Detail | 12 x IEC 60320 C19 |
Receptacle Detail | 6 x IEC 60320 C13 |
Receptacle Detail | 12 x IEC 60320 C19 |
Brand Name | Tripp Lite |
Brand Name | Tripp Lite |
Brand Name | Tripp Lite |
Country of origin | Taiwan |
Country of origin | Taiwan |
Country of origin | Taiwan |
Depth | 2.5" |
Depth | 2.5" |
Depth | 2.5" |
Environmental Certification | RoHS |
Environmental Certification | RoHS |
Environmental Certification | RoHS |
Environmentally Friendly | Yes |
Environmentally Friendly | Yes |
Environmentally Friendly | Yes |
Height | 70" |
Height | 70" |
Height | 70" |
Input current | 40 A |
Input current | 40 A |
Input current | 40 A |
Input voltage | 230 V AC |
Input voltage | 230 V AC |
Input voltage | 230 V AC |
Limited Warranty | 2 Year |
Limited Warranty | 2 Year |
Limited Warranty | 2 Year |
Management |
SNMP:
|
Management |
SNMP:
|
Management |
SNMP:
|
Manufacturer | Tripp Lite by Eaton |
Manufacturer | Tripp Lite by Eaton |
Manufacturer | Tripp Lite by Eaton |
Manufacturer Part Number | PDU3EVNR6H50A |
Manufacturer Part Number | PDU3EVNR6H50A |
Manufacturer Part Number | PDU3EVNR6H50A |
Manufacturer Website Address | http://www.tripplite.com |
Manufacturer Website Address | http://www.tripplite.com |
Manufacturer Website Address | http://www.tripplite.com |
Marketing Information | 14.4kW 3-Phase PDU Distributes and Monitors Network-Grade Power This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center computer room or high-density network closet the PDU3EVNR6H50A features six C13 and 12 C19 208V outlets in six breakered load banks which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged. Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time Not only can you remotely monitor voltage and frequency but the PDU3EVNR6H50A also allows metering of per-phase input current as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks as well as compare power usage among various devices. Built-In LX Platform Network Management Card Allows Remote Access 24/7 The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimal communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 FTP DHCP and NTP. Color Touchscreen LCD Gives You Important Data at a Glance An easy-to-navigate color touchscreen LCD reports network data including IP address input current level per phase and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected the LCD also displays status and environmental data including temperature and humidity. Easy to Install Vertically in an EIA-Standard 19 in. Rack The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a Hubbell 50A CS8365C 208V input connects the PDU to a compatible AC power source generator or protected UPS. TAA-Compliant for GSA Schedule Purchases The PDU3EVNR6H50A is compliant with the Federal Trade Agreements Act (TAA) which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. |
Marketing Information | 14.4kW 3-Phase PDU Distributes and Monitors Network-Grade Power This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center computer room or high-density network closet the PDU3EVNR6H50A features six C13 and 12 C19 208V outlets in six breakered load banks which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged. Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time Not only can you remotely monitor voltage and frequency but the PDU3EVNR6H50A also allows metering of per-phase input current as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks as well as compare power usage among various devices. Built-In LX Platform Network Management Card Allows Remote Access 24/7 The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimal communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 FTP DHCP and NTP. Color Touchscreen LCD Gives You Important Data at a Glance An easy-to-navigate color touchscreen LCD reports network data including IP address input current level per phase and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected the LCD also displays status and environmental data including temperature and humidity. Easy to Install Vertically in an EIA-Standard 19 in. Rack The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a Hubbell 50A CS8365C 208V input connects the PDU to a compatible AC power source generator or protected UPS. TAA-Compliant for GSA Schedule Purchases The PDU3EVNR6H50A is compliant with the Federal Trade Agreements Act (TAA) which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. |
Marketing Information | 14.4kW 3-Phase PDU Distributes and Monitors Network-Grade Power This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center computer room or high-density network closet the PDU3EVNR6H50A features six C13 and 12 C19 208V outlets in six breakered load banks which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged. Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time Not only can you remotely monitor voltage and frequency but the PDU3EVNR6H50A also allows metering of per-phase input current as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks as well as compare power usage among various devices. Built-In LX Platform Network Management Card Allows Remote Access 24/7 The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimal communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 FTP DHCP and NTP. Color Touchscreen LCD Gives You Important Data at a Glance An easy-to-navigate color touchscreen LCD reports network data including IP address input current level per phase and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected the LCD also displays status and environmental data including temperature and humidity. Easy to Install Vertically in an EIA-Standard 19 in. Rack The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a Hubbell 50A CS8365C 208V input connects the PDU to a compatible AC power source generator or protected UPS. TAA-Compliant for GSA Schedule Purchases The PDU3EVNR6H50A is compliant with the Federal Trade Agreements Act (TAA) which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. |
Mount Type | Rack-mountable |
Mount Type | Rack-mountable |
Mount Type | Rack-mountable |
Output voltage | 208 V AC |
Output voltage | 208 V AC |
Output voltage | 208 V AC |
Package Contents |
|
Package Contents |
|
Package Contents |
|
Plug/Connector Type | Hubbel CS8365C 50A |
Plug/Connector Type | Hubbel CS8365C 50A |
Plug/Connector Type | Hubbel CS8365C 50A |
Product Name | PDU3EVNR6H50A 18-Outlets PDU |
Product Name | PDU3EVNR6H50A 18-Outlets PDU |
Product Name | PDU3EVNR6H50A 18-Outlets PDU |
Product Type | PDU |
Product Type | PDU |
Product Type | PDU |
Protection Type | Overload Protection |
Protection Type | Overload Protection |
Protection Type | Overload Protection |
Rack Height | 0U |
Rack Height | 0U |
Rack Height | 0U |
Receptacle Type | IEC 60320 C13 |
Receptacle Type | IEC 60320 C13 |
Receptacle Type | IEC 60320 C19 |
Receptacle Type | IEC 60320 C19 |
Receptacle Type | IEC 60320 C13 |
Receptacle Type | IEC 60320 C19 |
UPC Alternates | 037332242259 |
UPC Alternates | 037332242259 |
UPC Alternates | 037332242259 |
Weight (Approximate) | 14.13 lb |
Weight (Approximate) | 14.13 lb |
Weight (Approximate) | 14.13 lb |
Material Safety Data Sheet
A Material Safety Data Sheet (MSDS) is a document that contains information on the potential hazards (health, fire, reactivity and environmental) and how to work safely with the chemical product.