Tripp Lite UPS Smart Online 3000VA 2700W Tower 120V LCD USB DB9 Ext Run - Tower - 3 Hour Recharge - 4.10 Minute Stand-by - 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Input - 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Output - 8 x NEMA 5-15/20R, 1 x NEMA L5-30R
Tower - 3 Hour Recharge - 4.10 Minute Stand-by - 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Input - 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Output - 8 x NEMA 5-15/20R, 1 x NEMA L5-30R
Bypass Switch | Automatic |
Bypass Switch | Automatic |
Load Capacity (VA) | 3000 VA |
Load Capacity (VA) | 3000 VA |
Load Capacity (W) | 2700 W |
Load Capacity (W) | 2700 W |
Receptacle Detail | 8 x NEMA 5-15/20R |
Receptacle Detail | 1 x NEMA L5-30R |
Receptacle Detail | 8 x NEMA 5-15/20R |
Receptacle Detail | 1 x NEMA L5-30R |
Backup/Run Time (Full Load) | 4.10 Minute |
Backup/Run Time (Full Load) | 4.10 Minute |
Backup/Run Time (Half Load) | 13.20 Minute |
Backup/Run Time (Half Load) | 13.20 Minute |
Brand Name | Tripp Lite |
Brand Name | Tripp Lite |
Certifications & Standards | |
Certifications & Standards | |
Country of origin | China |
Country of origin | China |
Depth | 19.5" |
Depth | 19.5" |
Form factor | Tower |
Form factor | Tower |
Height | 10.2" |
Height | 10.2" |
Hot Swappable | Yes |
Hot Swappable | Yes |
Input voltage | 127 V AC |
Input voltage | 115 V AC |
Input voltage | 110 V AC |
Input voltage | 115 V AC |
Input voltage | 110 V AC |
Input voltage | 100 V AC |
Input voltage | 120 V AC |
Input voltage | 127 V AC |
Input voltage | 100 V AC |
Input voltage | 120 V AC |
Limited Warranty | 2 Year |
Limited Warranty | 2 Year |
Load Capacity | 3000 VA/2700 W |
Load Capacity | 3000 VA/2700 W |
Manufacturer | Tripp Lite by Eaton |
Manufacturer | Tripp Lite by Eaton |
Manufacturer Part Number | SU3000XLCD |
Manufacturer Part Number | SU3000XLCD |
Manufacturer Website Address | http://www.tripplite.com |
Manufacturer Website Address | http://www.tripplite.com |
Marketing Information | Ideal for Protection of Mission-Critical Equipment The SU3000XLCD provides true on-line operation reliable battery backup and comprehensive power management capability in a compact tower form factor. Featuring a 3000VA/2700W capacity 9 AC outlets (8 5-15/20R 1 L5-30R) a 10-ft. cord with locking L5-30P plug USB/DB9 ports and a slot for an optional network management card options such as Tripp Lite's SNMPWEBCARD the SU3000XLCD offers a complete power protection solution for medium- to large-size servers storage devices telecom systems and other mission-critical equipment.
True On-Line Operation with Pure Sine Wave Output and Zero Transfer Time The SU3000XLCD provides the highest level of protection available for mission-critical equipment. It actively converts raw incoming AC power to DC then re-converts it back to regulated filtered AC output with a pure sine wave completely isolating connected components from all power problems. Zero transfer time between AC and battery operation maintains continuous output and further protects connected equipment from the disruptive effects of blackouts and severe low-voltage conditions. Sine wave output guarantees compatibility with all equipment types.
Individually Controllable Outlets The SU3000XLCD includes 2 load banks of 4 outlets each that are individually controllable via a software interface for remote reboot of locked-up equipment or load shedding to maximize battery backup time for mission-critical equipment.
Reliable Expandable Battery Backup UPS battery backup keeps connected equipment operational through short power failures and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU3000XLCD features a large internal battery set that provides 13.2 minutes of battery support for a half load (1350 watts) and 4.1 minutes for a full load (2700 watts). During normal operation incoming utility power keeps the UPS battery fully charged so that backup power will always be available if needed. Intelligent battery management system extends battery life. For mission-critical applications demanding continuous uptime the fully scalable SU3000XLCD can provide expandable runtime with optional external battery packs (Tripp Lite model BP72V15-2U or BP72V28RT-3U) sold separately.
High Power Factor and Highly Efficient Operation Reduces BTU Output The SU3000XLCD features a high 0.9 power factor and an optional highly efficient economy mode setting that can significantly reduce a facility's energy costs. In economy mode the UPS operates with 98% efficiency minimizing heat output reducing cooling requirements and consuming less electricity.
AC and Tel/Ethernet Line Surge Suppression A sudden power surge or spike can damage or destroy electronic components and wipe out irreplaceable data. The SU3000XLCD features a 570-joule surge suppression rating to protect connected components and data from the harmful effects of power surges. One set of tel/Ethernet (RJ45) jacks provides surge protection for a standard phone or network connection (cable not included).
EMI/RFI Line Noise Filtering Various electrical and radio sources can cause disruptive interference on the AC line. |
Marketing Information | Ideal for Protection of Mission-Critical Equipment The SU3000XLCD provides true on-line operation reliable battery backup and comprehensive power management capability in a compact tower form factor. Featuring a 3000VA/2700W capacity 9 AC outlets (8 5-15/20R 1 L5-30R) a 10-ft. cord with locking L5-30P plug USB/DB9 ports and a slot for an optional network management card options such as Tripp Lite's SNMPWEBCARD the SU3000XLCD offers a complete power protection solution for medium- to large-size servers storage devices telecom systems and other mission-critical equipment.
True On-Line Operation with Pure Sine Wave Output and Zero Transfer Time The SU3000XLCD provides the highest level of protection available for mission-critical equipment. It actively converts raw incoming AC power to DC then re-converts it back to regulated filtered AC output with a pure sine wave completely isolating connected components from all power problems. Zero transfer time between AC and battery operation maintains continuous output and further protects connected equipment from the disruptive effects of blackouts and severe low-voltage conditions. Sine wave output guarantees compatibility with all equipment types.
Individually Controllable Outlets The SU3000XLCD includes 2 load banks of 4 outlets each that are individually controllable via a software interface for remote reboot of locked-up equipment or load shedding to maximize battery backup time for mission-critical equipment.
Reliable Expandable Battery Backup UPS battery backup keeps connected equipment operational through short power failures and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU3000XLCD features a large internal battery set that provides 13.2 minutes of battery support for a half load (1350 watts) and 4.1 minutes for a full load (2700 watts). During normal operation incoming utility power keeps the UPS battery fully charged so that backup power will always be available if needed. Intelligent battery management system extends battery life. For mission-critical applications demanding continuous uptime the fully scalable SU3000XLCD can provide expandable runtime with optional external battery packs (Tripp Lite model BP72V15-2U or BP72V28RT-3U) sold separately.
High Power Factor and Highly Efficient Operation Reduces BTU Output The SU3000XLCD features a high 0.9 power factor and an optional highly efficient economy mode setting that can significantly reduce a facility's energy costs. In economy mode the UPS operates with 98% efficiency minimizing heat output reducing cooling requirements and consuming less electricity.
AC and Tel/Ethernet Line Surge Suppression A sudden power surge or spike can damage or destroy electronic components and wipe out irreplaceable data. The SU3000XLCD features a 570-joule surge suppression rating to protect connected components and data from the harmful effects of power surges. One set of tel/Ethernet (RJ45) jacks provides surge protection for a standard phone or network connection (cable not included).
EMI/RFI Line Noise Filtering Various electrical and radio sources can cause disruptive interference on the AC line. |
Network Management | SNMP Manageable |
Network Management | SNMP Manageable |
Package Contents | - SmartOnline SU3000XLCD 3000VA Tower UPS
- Poweralert Software CD
- Owner's Manual with Warranty Information
- EPO (Emergency Power Off) Cable
- USB Cable
- DB9 Cable
|
Package Contents | - SmartOnline SU3000XLCD 3000VA Tower UPS
- Poweralert Software CD
- Owner's Manual with Warranty Information
- EPO (Emergency Power Off) Cable
- USB Cable
- DB9 Cable
|
Plug/Connector Type | NEMA L5-30P |
Plug/Connector Type | NEMA L5-30P |
Product Line | SmartOnline |
Product Line | SmartOnline |
Product Name | SmartOnline SU3000XLCD 3000VA Tower UPS |
Product Name | SmartOnline SU3000XLCD 3000VA Tower UPS |
Product Type | Double Conversion Online UPS |
Product Type | Dual Conversion Online UPS |
Product Type | Dual Conversion Online UPS |
Receptacle Type | NEMA L5-30R |
Receptacle Type | NEMA L5-30R |
Receptacle Type | NEMA 5-15/20R |
Receptacle Type | NEMA 5-15/20R |
Software Included | PowerAlert Software |
Software Included | PowerAlert Software |
Transfer Time | 0 ns |
Transfer Time | 0 ns |
Typical Battery Recharge Time | 3 Hour |
Typical Battery Recharge Time | 3 Hour |
UPC Alternates | 037332158871 |
UPC Alternates | 037332158871 |
Weight (Approximate) | 70.50 lb |
Weight (Approximate) | 70.50 lb |
Width | 9" |
Width | 9" |